01.02
Response
Remedy
Program continua-
tion by
16 925
Explanation
Response
Remedy
Program continua-
tion by
16 931
Explanation
Response
Remedy
Program continua-
tion by
17 001
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Alarm display.
Save the tool data to MMC and recopy them when the program test is com-
pleted.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 program control: action %2 not allowed in the current state
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
The action has been denied, since a process change is being carried out. Proc-
ess change means mode change, switching on or off Overstore.
Example:
NC Start during mode change from AUTOMATIC to MDA.
Alarm display.
Repeat the command.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 subprogram: action %2 maximum stack level exceeded
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
The current operation can be interrupted by various actions.
Depending on the action, control-internal programs are activated. These pro-
grams can be interrupted in similar fashion as the NC program. For memory
reasons, any nesting depth of the control-internal programs is not possible.
Example:
Do not interrupt the approach block of a repositioning process repeatedly, but
wait until the approach block is executed.
Possible actions are mode change, block suppression, overstore, etc.
Alarm display
Initiate block change and repeat the action.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 no memory left for tool or magazine data
%1 = Channel number
%2 = Block number, label
The number of the tool data in the NC is limited.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Delete tools not used.
Press the RESET key to clear the alarm. Restart part program.