1 Alarms
26 005
Explanation
Response
Remedy
Program continua-
tion by
26 006
Explanation
Response
Remedy
Program continua-
tion by
26 014
Explanation
Response
1-86
Axis %1 invalid output rating configured
%1 = Axis name, spindle number
The output evaluation of the analog speed setpoint set in MD 32 260
RATED_VELO is illegal (e.g. zero).
Mode group ('BAG') not ready for operation.
Channel not ready for operation.
NC Start inhibited.
NC Stop at alarm.
The NC changes to follow-up mode.
Alarm display.
Interface signals are set.
Enter the motor nominal speed in MD 32 260 RATED_VELO.
Press the RESET key to clear the alarm. Restart part program.
Axis %1 encoder %2 encoder type/output type %3 not possible
%1 = Axis name, spindle number
%2 = Encoder number
%3 = Encoder type/output type
Permissible settings:
MD 30 240 ENC_TYPE
MD 30 130 CTRLOUT_TYPE
Mode group ('BAG') not ready for operation.
Channel not ready for operation.
NC Start inhibited.
NC Stop at alarm.
The NC changes to follow-up mode.
Alarm display.
Interface signals are set.
Check MD 32 240 ENC_TYPE and/or MD 30 130 CTRL_OUT_TYPE and
correct if necessary.
Control system OFF-ON.
Axis %1 machine data %2 invalid value
%1 = Axis name, spindle number
%2 = String: MD identifier
MD contains invalid value.
Mode group ('BAG') not ready for operation.
Channel not ready for operation.
NC Start inhibited.
NC Stop at alarm.
The NC changes to follow-up mode.
6FC5598-3AA20-0BP2
= 0
Simulation
= 2
Square-wave encoder
= 3
Step-switching motor selection
= 0
Simulation
= 1
Standard
= 2
Step-switching motor selection
© Siemens AG 2002 All Rights Reserved