Response
Remedy
Program continua-
tion by
10 881
Explanation
Response
Remedy
Program continua-
tion by
10 882
Explanation
Response
Remedy
Program continua-
tion by
10 900
Explanation
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Alarm display.
Interface signals are set.
NC Start inhibited.
Modify part program such that the permissible number of empty blocks is not
exceeded.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 overflow of local block buffer when inserting
chamfer or radius
%1 = Channel number
%2 = Block number, label
The number of empty blocks without contour information between two blocks
which contain contour elements and which are to be linked with a chamfer or
radius (CHF, RND) is so large that the internal buffer memory is too small..
Alarm display.
Interface signals are set.
NC Start inhibited.
Modify the part program such that the number of empty blocks is reduced.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 do not activate chamfer or radius in blocks without
traversing
%1 = Channel number
%2 = Block number, label
No chamfer or radius has been inserted between 2 linear or circle contours
(chamfer edging), because:
no straight line or circle contour exists in the plane
a movement exists outside the plane
the level has been changed
the permissible number of empty blocks without traversing information
(dummy blocks) has been exceeded
Alarm display.
Interface signals are set.
NC Start inhibited.
Correct the part program with respect of the error mentioned above.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 no S value programmed for constant cutting speed
%1 = Channel number
%2 = Block number, label
When G96 is active, the constant cutting speed under address S is missing.