1 Alarms
14 051
Explanation
Response
Remedy
Program continua-
tion by
14 080
Explanation
Response
Remedy
Program continua-
tion by
14 092
Explanation
Response
Remedy
Program continua-
tion by
1-44
Channel %1 block %2 arithmetic error in part program
%1 = Channel number
%2 = Block number, label
With the calculation of an arithmetic expression, an overflow occurred
(e.g. division by zero).
The value range that can be represented for a certain data type has been
exceeded.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Analyze the program and correct the faulty program section.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 jump destination not found
%1 = Channel number
%2 = Block number, label
The jump target of conditioned and unconditioned jumps with in the program
must be a block with a label (symbolic name instead of block number). If no
jump target with the specified label is found when searching in the pro-
grammed direction, this alarm is displayed.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Check the NC program for the following possible errors:
1. Check whether the target designation is identical to the label.
2. Is the jump direction correct?
3.
Has the label been completed with a colon?
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 axis %3 has wrong axis type
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Correct part program.
Press the RESET key to clear the alarm. Restart part program.