1 Alarms
16 903
Explanation
Response
Remedy
Program continua-
tion by
16 904
Explanation
Response
Remedy
Program continua-
tion by
16 905
Explanation
Response
Remedy
Program continua-
tion by
16 906
Explanation
Response
Remedy
Program continua-
tion by
1-60
Channel %1 program control: action %2 not allowed in the current state
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
The action concerned cannot be processed at the moment. This can occur when
importing machine data, for example.
Alarm display.
Wait until the previous operation is completed, or cancel the operation with
reset and repeat the action.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 program control: action %2 not allowed in the current state
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
Processing (program, Jog, block search, reference point, ...) cannot be started
or continued in the current state.
Alarm display
Check program state and channel state.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 program control: action %2 not allowed
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
Processing cannot be started or continued. A start will only be accepted if an
NCK function can be started.
Example: A start is accepted in Jog mode, for example, if the function genera-
tor is active or a Jog movement has been stopped by the Stop key beforehand.
Alarm display.
Check program state and channel state.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 program control: action %2 is aborted because of an active
alarm
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
The action has been canceled due to an alarm.
Processing cannot be started or continued. A start will only be accepted if an
NCK function can be started.
Alarm display.
Eliminate the error and acknowledge the alarm. Then restart the process.
Press the Clear key to clear the alarm. No further operation required.