Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 62

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

1 Alarms
Program continua-
tion by
16 913
Explanation
Response
Remedy
Program continua-
tion by
16 914
Explanation
Response
Remedy
Program continua-
tion by
16 915
Explanation
Response
Remedy
Program continua-
tion by
1-62
Press the Clear key to clear the alarm. No further operation required.
BAG %1 channel %2 mode change: action %3 not allowed
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name (see Section 1.4 Action List)
Changing to the desired mode is not allowed. The change is only allowed in
Reset state.
Example:
The program execution is stopped in AUTO mode by NC Stop. Then, a mode
change to JOG is carried out program state "interrupted"). From this operating
mode, you can change only to AUTO mode, but not to MDA!
Alarm display.
Either press the Reset key , thus resetting the program execution, or select the
mode in which the program execution has been executed until this moment.
Press the Clear key to clear the alarm. No further operation required.
Mode group %1 channel %2 mode change: action %3 not allowed
%1 = Channel number
%2 = Mode group number
%3 = Action number/action name (see Section 1.4 Action List)
Wrong mode change, e.g.: AUTO → MDAREF
Alarm display.
Check operation or selected mode.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 action %2 in the current block not allowed
%1 = Channel number
%2 = Action number/action name (see Section 1.4 Action List)
Reorganization of block processing is currently not possible. Mode change
cannot be carried out.
The 2nd parameter describes the action recommended to interrupt block exe-
cution.
Alarm display.
Continue program execution up to a reorganized NC block or modify part
program.
Press the Clear key to clear the alarm. No further operation required.