1 Alarms
5 000
Explanation
Response
Remedy
Program continua-
tion by
6 000
Explanation
Response
Remedy
Program continua-
tion by
6 020
Explanation
Response
Remedy
Program continua-
tion by
6 500
Explanation
Response
Remedy
1-18
Communication job not executed
The communication task (data exchange between NCK and MMC), e.g. load-
ing of an NC part program) cannot be executed due to insufficient memory.
Cause: too many parallel communication jobs.
Alarm display.
No remedial action possible - the operating action that resulted in the alarm
message must be repeated. Press Cancel to clear the alarm display.
Press the Clear key to clear the alarm. No further operation required.
Memory reorganized using standard machine data
The memory management could not realize the NC user memory mapping with
the values provided in the machine data, because the total memory is used by
the NC user both as a dynamic and a static memory (e.g. for the number of tool
offsets, number of directories and files, etc.) and is therefore not sufficient.
Alarm display.
Interface signals are set.
NC Start inhibited.
NC Stop at alarm.
Redefine NC memory mapping!
It is not possible to specify a certain MD as an alarm cause for the NC user
memory assignment. The MD that has caused the alarm must therefore be de-
termined on the base of the default values in the machine data and by modify-
ing the user-specific memory assignment step by step.
In most cases, not only an individual MD is selected too large, and it is there-
fore recommended to reduce the memory area in several MDs by a certain
fraction.
Press the RESET key to clear the alarm. Restart part program.
Machine data have been altered - now memory is reorganized
Machine data defining the NC user memory mapping have been altered. The
data management has re-mapped the memory with respect of the altered ma-
chine data.
Alarm display.
No remedial action required. Any user data needed must be re-entered.
Press the RESET key to clear the alarm. Restart part program.
NC memory is full
Too many part programs have been loaded. The job cannot be carried out.
This error may concern files of the NC file system (part of NC memory), such
as initialization files, NC programs, etc., during commissioning.
Alarm display.
Delete or unload files (e.g. part programs).