1 Alarms
Program continua-
tion by
14 920
Explanation
Response
Remedy
Program continua-
tion by
15 170
Explanation
Response
Remedy
Program continua-
tion by
15 175
Explanation
Response
Remedy
Program continua-
tion by
1-50
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 intermediate point of circle incorrect
%1 = Channel number
%2 = Block number, label
When programming a circle via an intermediate point, all 3 points (start, end
and intermediate point) are on a straight line, and the intermediate point (pro-
grammed by the interpolation parameters I, J, K) is not between the start and
the end point.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Either place the position of the intermediate point with the parameters I, J and
K such that its position will be really between the circle start and the end point,
or sacrifice of this kind of circle programming and program the circle with
radius and opening angle or center point parameters.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 program %3 could not be compiled
%1 = Channel number
%2 = Block number, label
%3 = String
An error occurred in compilation mode. The (compiler) message displayed
after the error refers to the program specified here.
Alarm display.
Correct the part program.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 program %3 interfaces could not be built
%1 = Channel number
%2 = Block number, label
%3 = String
An error occurred during the interface creation mode. The (compiler) error
message displayed after the error occurred refers to the program specified here.
Alarm display.
Correct the part program.
Press the Clear key to clear the alarm. No further operation required.
6FC5598-3AA20-0BP2
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
01.02