1 Alarms
14 601
Explanation
Response
Remedy
Program continua-
tion by
14 710
Explanation
Response
Remedy
Program continua-
tion by
14 750
Explanation
Response
1-46
Channel %1 block %2 reload buffer cannot be cleared
%1 = Channel number
%2 = Block number, label
The reload buffer for "Execution from external" could not be cleared; probable
cause:
- MMC-PLC communication not completed.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
All reload buffers are cleared on Power On.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 error during phase %3 of INIT block generation
%1 = Channel number
%2 = Block number, label
%3 = Index for section
When the control system boots and is reset, initialization blocks are generated.
Due to incorrect machine data settings, errors might occur.
Parameter %3 indicates in which section of ini block generation the error oc-
curred:
Section 0:
Error in synchronization (program advance/main run).
Section 1:
Error when selecting tool length compensation.
Section 2:
Error when selecting transformation.
Section 3:
Error when selecting zero offset.
During booting, the cycle interfaces are additionally read in. If an error occurs
during this process, "Section 5" is signaled.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
In section 0-3:
Load standard machine data
In section 5:
Reload cycles
Restart
Channel %1 block %2 too many auxiliary functions programmed
%1 = Channel number
%2 = Block number, label
More than 10 auxiliary functions have been programmed in a block.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.