Download Print this page

Siemens SINUMERIK 802S Diagnostics Manual page 51

Hide thumbs Also See for SINUMERIK 802S:

Advertisement

01.02
15 180
Explanation
Response
Remedy
Program continua-
tion by
15 185
Explanation
Response
Remedy
Program continua-
tion by
15 300
Explanation
Response
Remedy
Program continua-
tion by
15 320
Explanation
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Channel %1 block %2 program %3 cannot be executed as INI file
%1 = Channel number
%2 = Block number, label
%3 = String
Errors occurred when reading in data as an INI file. The displayed error mes-
sage refers to the program specified here.
Alarm display.
Correct the part program.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 %2 Errors in INI file
%1 = Channel number
%2 = Number of detected errors
Errors have been detected when processing an INI file.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Correct INI file or MD and create new INI file (via 'upload').
Power ON
Channel %1 block %2 invalid number-of-passed-blocks during block
search
%1 = Channel number
%2 = Block number, label
A negative number of passes has been input in the P column (Number of
Passes) when the function "Block Search with Calculation" was executed. The
permissible value range is P 1 - P 9 999.
Alarm display.
Enter only positive numbers of passes within the value range.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 invalid block search command
%1 = Channel number
%2 = Block number, label
The search job (type of searching target) is less than "1" or greater than "5". It
is entered in the Type column of the block search window. Permissible search
jobs are:
Type
Meaning
6FC5598-3AA20-0BP2
1 Alarms
1-51

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Sinumerik 802c