1 Alarms
17 010
Explanation
Response
Remedy
Program continua-
tion by
17 020
Explanation
Response
Remedy
Program continua-
tion by
17 070
Explanation
Response
Remedy
Program continua-
tion by
1-66
Channel %1 block %2 no memory left for symbol
%1 = Channel number
%2 = Block number, label
When executing/importing files of the active user memory, it was detected that
the memory available is not sufficient (e.g. for creating the tool offset mem-
ory).
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Make more memory space available for subroutine calls and tool offsets.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 1st array index out of range
%1 = Channel number
%2 = Block number, label
A read or write access to a field variable (e.g. arithmetic parameter) with inva-
lid 1st field index has been programmed.
For example, R2000 = 5; parameter number 2000 not defined.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Correct the specification of the field elements for the access instruction with
respect to the defined size.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 data is write protected
%1 = Channel number
%2 = Block number, label
You have tried to write into a write-protected variable or an MD, for which you
have no right to access.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Remove the write accesses to write-protected variables from the NC program
or the machine data file.
Press the RESET key to clear the alarm. Restart part program.