01.02
14 095
Explanation
Response
Remedy
Program continua-
tion by
14 130
Explanation
Response
Remedy
Program continua-
tion by
14 600
Explanation
Response
Remedy
Program continua-
tion by
© Siemens AG 2002 All Rights Reserved
SINUMERIK 802S/802C (DG)
Channel %1 block %2 circle programmed with zero radius
%1 = Channel number
%2 = Block number, label
Under the keyword CR=.. for the circle radius, value "0" has been pro-
grammed.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Circle radius less than
circle)
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 too many initialization values given
%1 = Channel number
%2 = Block number, label
When assigning the field via SET, more initialization values have been speci-
fied for the program execution than field elements exist.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Reduce the number of initialization values.
Press the RESET key to clear the alarm. Restart part program.
Channel %1 block %2 buffer for sequential reload cannot be established
%1 = Channel number
%2 = Block number, label
When loading the INITIAL_INI block, the reload buffer could not be estab-
lished because of insufficient memory in the RAM of the NCK.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Create free space in the NCK area, for example, by deleting part programs no
longer used.
Press the RESET key to clear the alarm. Restart part program.
CR=.. positive (circle is less than or equal to semi-
CR=.. negative (circle is greater than a semi-circle)
6FC5598-3AA20-0BP2