1 Alarms
Response
Remedy
Program continua-
tion by
15 330
Explanation
Response
Remedy
Program continua-
tion by
15 340
Explanation
Response
Remedy
Program continua-
tion by
15 350
Explanation
Response
Remedy
Program continua-
tion by
1-52
1
Find block number
2
Find label
3
Find string
4
Find program name
5
Find line number in file
Alarm display.
Alter search job.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 invalid block number as target of block search
%1 = Channel number
%2 = Block number, label
Syntax error! Only positive integer numbers are permitted as block numbers.
For main blocks, ":" must be written in front of them, and an "N" must be
written in front of auxiliary blocks.
Alarm display.
Repeat your entry with the corrected block number.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 invalid label as target of block search
%1 = Channel number
%2 = Block number, label
Syntax error! A label must contain at least 2 and not more than 32 characters
whereby the first two characters must be letters or underscores. Labels must
end in a colon.
Alarm display.
Repeat your entry with the corrected label.
Press the Clear key to clear the alarm. No further operation required.
Channel %1 block %2 target of block search not found
%1 = Channel number
%2 = Block number, label
The specified program has been browsed up to the end of the program without
finding the preselected search target.
Alarm display.
Interface signals are set.
Interpreter stop.
NC Start inhibited.
Check the part program, alter the search target (type error in part program) and
restart search.
Press the RESET key to clear the alarm. Restart part program.
6FC5598-3AA20-0BP2
© Siemens AG 2002 All Rights Reserved