Connect The Cables - Avaya S8700 Installing

With avaya mcc1 or scc1 media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than
10 seconds. During the test, all the ports on the unit are disabled and the LEDs light up. For
more information on the test, refer to the user's guide that comes with the unit.

Connect the Cables

All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for
all data wires (pins 1, 2, 3 and 6).
1
2
7
3
4
5
6
Data &
Power
Data
Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including
all 8 wires (4 pairs) as shown in
page
265.
Connecting telephones and other end devices to the 1152A1 PDU
Ethernet
Switch/Hub
data
1
data
2
data
3
spare
4
spare
5
data
6
spare
7
spare
8
For Data-In ports connect the Ethernet cable leading from the Ethernet Switch/Hub to the Data
port. For Data & Power Out ports connect the Ethernet cable leading to the telephone or other
end device to the corresponding Data & Power port.
NOTE:
Be certain to connect correspondingly numbered Data and Data & Power ports.
Connecting cables to telephones and other end devices
The 1152A1 PDU contains line-sensing capabilities that enable it to send power only to end
devices designed to receive power from the LAN. These end devices, termed Power over LAN
Enabled, receive power once they are connected to the 1152A1 PDU.
8
13
14
9
10
11
12
15
''Connecting cables to telephones and other end devices'' on
1152A1 Power Distribution Unit
RJ-45 IN
RJ-45 OUT
1
2
3
4
5
6
7
8
May 2003
Installing and Wiring Telephone Power Supplies
19
20
16
17
18
21
22
23
End Device
data
1
1
data
2
2
data
3
3
DC +
4
4
DC +
5
5
data
6
6
DC -
7
7
DC -
8
8
265
24
1152A1 Power
Distribution Unit
AC
Console
48Vdc

Advertisement