Connect Dc Power And Ground - Avaya S8700 Installing

With avaya mcc1 or scc1 media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Some media gateways contain a J58890CE-2 AC Power Distribution Unit without an optional
battery charger. Install the shorting cable only when a battery charger is not installed. If you do
not install the shorting cable or a battery charger, then an alarm appears.
1
Set the circuit breakers on the power distribution unit OFF. See
Installation'' on page
At the rear of the media gateway, insert the shorting cable (H600-442-G1) into J11. The
2
cable is keyed so it can fit only 1 way.
Shorting Cable Installation
Figure notes
1
Shorting Cable (H600-442-G1) (if battery
charger is not installed)
Connect AC Power
1
Set the main circuit breakers on the power distribution unit OFF.
Connect media gateway AC line cords to the AC power receptacles.
2
NOTE:
Do not power up the S8700 Multi-Connect configuration at this time.

Connect DC Power and Ground

!
CAUTION:
Grounding of the S8700 Multi-Connect configuration shall comply with the general rules
for grounding contained in Article 250 of the National Electrical Code, NFPA 70. For
more information, refer to
81.
Approved
Grounds.
May 2003
''Shorting Cable
2
J11
81