Table 7.2 Error messages displayed on the operator panel (1/3)

No.
Message
1 OBP:ERROR
Check errorlogs
2 OBP:ERROR
RED state trap
3 POST:ERxxxxxxxx
SB#L
4 POST:ERxxxxxxxx
SCFA#L
5 POST:ERxxxxxxxx
SB#L CPU#NN
6 POST:ERxxxxxxxx
SB#L DIMM#NN
7 POST:ERxxxxxxxx
SB#L DIMM Conf
8 POST:ERxxxxxxxx
SCFA#L PCI#NN
9 POST:ERxxxxxxxx
PCIBOX#L PCI#NN
10 INPUT#L FAIL
#L: Location number of the unit where the error occurred
U41261-J-Z816-4-76
Explanation
OBP detected an error.
A RED state trap occurred.
An error occurred in the system board or in a
unit on the system board.
An error occurred in an SCFA or in a unit on
the SCFA.
An error occurred in the CPU.
A memory error occurred.
A memory configuration error occurred.
An error occurred in the PCI adapter on
SCFA.
An error occurred in the PCI adapter on
PCIBOX.
An input power error occurred.
7.3 Error Messages Displayed on the Operator Panel
This message is displayed
when the Cursor switch is
pressed.
This message is displayed
when the Cursor switch is
pressed
This message is displayed
when the Cursor switch is
pressed.
This message is displayed
when the Cursor switch is
pressed.
This message is displayed
when the Cursor switch is
pressed.NN: Unit number
This message is displayed
when the Cursor switch is
pressed.NN: Unit number
This message is displayed
when the Cursor switch is
pressed.
This message is displayed
when the Cursor switch is
pressed.
NN: Unit number
This message is displayed
when the Cursor switch is
pressed.
NN: Unit number
Remarks
-
-
-
-
-
-
-
-
-
-