l Size
Figure 4.3 Back of the PCIBOX (showing location of PCI slots)
4.3.4

Connecting signal cables

This section explains how to connect this unit via the signal cables to a
PRIMEPOWER850/650.
• Connection to PRIMEPOWER650
Only one PCIBOX can be connected to a PRIMEPOWER650.
The following signal cables are supplied with this unit:
l CH-IF cable (2 m) x 1
l LCI cable (3 m) x 1
Use these signal cables to connect PCIBOX to a PRIMEPOWER650 as shown in
Figure
4.4.
U41261-J-Z816-4-76
- A PCI card that can only operate on 5 V can operate in a 5-V slot, but
cannot operate in a 3.3-V slot.
- A universal PCI card (a PCI card that can operate on either 3.3 V or 5
V) can operate in either type slot.