Installation Specifications; Table 4.1 Installation Specifications Of The Pcibox - Fujitsu PRIMEPOWER850 User Manual

Table of Contents

Advertisement

CHAPTER 4 PCIBOX
4.3.2

Installation specifications

Table 4.1

Table 4.1 Installation specifications of the PCIBOX (1/2)

Item
Weight
Power supply Input voltage
Input
frequency
Maximum
100V
current
200V (Note 2) 1.9 A (per cable)
consumption
Input Power
Leakage current
Ground resistance
Temperature
Operating
(Note 3)
Not operating 0 - 50 °C ( +32 ~ +122 °F)
Humidity
Operating
Not operating 8 ~ 80 % RH (Non-Condensing)
Heat dissipation
Vibration
Operating
Not operating 0.4G
Note 1: Not including the rack-mount rails
Note 2: Use of this unit at 200 VAC requires an option, which must be ordered.
Note 3: A warning message appears during operation if the ambient temperature
exceeds
35 °C (95°F). Take immediate corrective action.
102
lists the installation specifications for the PCIBOX.
33 kg (72.8 lb.) (maximum) (Note 1)
Single phase, 100 to 120 VAC or 200 to 240 VAC (±10%)
50/60 Hz (+2 / -4 %)
3.8 A (per cable)
375 VA
Less than 0.75 mA (per cable)
Less than 100 Ω
5 - 35 °C ( +41 ~ +95 °F)
[When installed at height of 0 to 1500 m (0 to 4921.2 ft) above sea level]
5 - 33 °C ( +41 ~ +91.4 °F)
[When installed at height of 1500 to 2000 m (4921.2 to 6561.6 ft) above
sea level]
5 - 32 °C ( +41 ~ +89.6 °F)
[When installed at height of 2000 to 2500 m (6561.6 to 8202 ft) above sea
level]
5 - 30 °C ( +41 ~ +86 °F)
[When installed at height of 2500 to 3000 m (8202 to 9842.4 ft) above sea
level]
20 ~ 80 % RH (Non-Condensing)
1260 kJ / hr (1195 BTU / hr)
0.2 G
Specifications