Fujitsu PRIMEPOWER850 User Manual page 165

Table of Contents

Advertisement

• Check command
ok printenv boot-wait-time
l When set value is zero, the following line appears:
boot-wait-time=0
• Setting command
l To set waiting time of 300 seconds, enter the following command:
ok setenv boot-wait-time 300
(2) diag-retry
If an error is detected in accessing to the target disk during the boot-up process of the
main unit, attempts to shut down and reboot the target disk unit through a retry
process may possibly run the target disk unit.
This situation could occur if the diag-retry variable is set to on and the system is
configured to enable automatic shutdown and then reboot. The variable default value
is off.
(3) boot-device
Sets boot-up target disk. This value is set by the install program during the OS
installation. This setting is enabled when the value of diag-switch? in the OBP
environment is set to false.
(4) boot-file
Sets a boot file. This setting is enabled when the value of diag-switch? in the OBP
environment is set to false.
(5) scsi-initiator-id
Sets the host side address of the SCSI bus. Range is from 0 to 7. The default value is
7.