CHAPTER 6 RCI Commands
(2) Command display example
The display that follows shows the RCI configuration settings from the last executed
rci-config command.
ok rci-config
HOST:
addres: 000101ff mode: 010038a0 status: c000
LIST:
address status device-class sub-class
000101ff 90 0001 01
000301ff 90 0100 01
000302ff 90 0201 01
(3) Example of how to use commands
Set the MODE switch on the main unit to MAINTENANCE and connect the RCI
cable. Then turn on the power and enter the following commands from the ok prompt.
• Initially connecting units
To initially connect units, enter the following commands:
ok rci-config 1 1
ok rci-configio-init
• Adding I/O units later on
To add I/O units later on, enter the following command:
ok rci-configio
• Adding host nodes
To add host nodes, enter the following command. Make the settings for only the node
to be added.
ok rci-config n m
ok rci-configio
In the above command, the value entered for n is the node address of the connected
I/O unit, and the value entered for m is the number of host nodes.
After making the above settings, execute the rci-config command to verify that the
settings were made correctly. After set-up is complete, return the MODE switch to the
regular operation setting (UNLOCK or LOCK).