5.5
Connecting cables
5.5.1
Notes on connecting/disconnecting cables
CAUTION
▶
Always read the documentation supplied with the device you wish
to connect.
▶
Never connect, or disconnect cables during a thunderstorm.
▶
Never pull on a cable when disconnecting it. Always take hold of
the cable by the plug.
▶
Follow the sequence described below to connect or disconnect
external devices to or from the server.
▶
Ensure that you wait for 10 seconds or more after shutdown before
turning the server on.
Connecting cables
▶ Switch off the server and equipment switches.
▶ Disconnect all power cords from the properly grounded power outlets.
▶ Disconnect the DC power cord with earth grounding conductor from the
properly DC source and earth ground stud or end.
▶ Connect all cables to the server and peripherals.
▶ Connect all data communication cables into the utility sockets.
▶ Connect all power cords into the properly grounded power outlets.
▶ Connect the DC power cord with earth grounding conductor from the
properly DC source and earth ground stud or end.
Disconnecting cables
▶ Switch off the server and equipment switches.
▶ Disconnect all power cords from the properly grounded power outlets.
▶ Disconnect the DC power cord with earth grounding conductor from the
properly DC source and earth ground stud or end.
RX2540 M6
Operating Manual
Starting up
69