Corrective Function

2-5

Corrective Function

2-5-1
Adjustment of Frequency Setting Value, Output Frequency Bias
(No. 23) and Gain (No. 22)
Description
Select PRGM Mode.
(Bias)
Select constant (No. 23).
Data (No. 23) are displayed.
Change the set value.
Description
(Gain)
Select constant (No. 22).
Data (No. 22) are displayed.
Change the set value.
34
Any desired value of output frequency for frequency set value (0 to
10 V or 4 to 20 mA) can be set.
Example
Adjust so as to obtain 10% speed (6 Hz) at frequency setting volt-
age 0 V and 100% speed (60 Hz) at 8 V.
Key Operation
PRGM
ENTER
DATA
ENTER
RESET
DATA
ENTER
Key Operation
NO
DSPL
DATA
ENTER
RESET
DATA
ENTER
Note
1. The gain can be calculated using the following equations:
100 - b
x =
a
a: Setting voltage at 100% frequency
b: Bias level (%)
G: Gain set value
For example, if 100% speed (60 Hz) is obtained at 8 V, a=8. If
10% speed (6 Hz) is obtained at a frequency setting voltage of
0 V, b=10. In this case, the above equations yield G=1.23.
2. No. 22 and No. 23 can also be adjusted in DRIVE Mode.
Digital Operator Display
(No. 22)
REF.
Input
level
(%)
BIAS
(No. 23)
(10 % = 0.1)
Digital Operator Display
10x + b
. . . (1)
G =
100
Section 2-5
Gain
123
100
Gain
10
0
8 V
FREQ. setting voltage (V)
(See note.)
. . . (2)
10 V