Entering Values For Machine Data - Siemens SIMATIC S7-300 Manual

Fm 354 servo drive positioning module
Hide thumbs Also See for SIMATIC S7-300:
Table of Contents

Advertisement

Defining Parameters of the FM 354
Entering values
In "Parameterize FM 354" select the menu File New Machine Data to
call up the following display.
Fig. 5-4
Enter the machine data in the tab windows.
You can also enter your values in a table by selecting View Table form.
When creating the MD DBs you must follow the instructions in Section 7
"Starting up the FM 354".
Note
The measurement system (MD7) must match the measurement system speci-
fied in the other DBs.
The measurement system raster (MSR) is the smallest distance unit in the
active system of measurement.
If at some point you have failed to take this precaution:
1. Delete all data blocks (which do not match the measurement system) or
2. Modify the other data blocks on the PG.
3. Reload the data blocks to the FM 354.
5-10

Entering values for machine data

clear the memory of the FM 354 completely.