Troubleshooting
Table 11-8
General data errors, machine data errors, traversing program errors, continued
Cl.
No.
General data errors
4 (04) 10 (0A)
Zero offset value, offset value incorrect
Cause
Effect
Elimina-
tion
4 (04) 11 (0B)
Set actual value, actual value incorrect
Cause
Effect
Elimina-
tion
4 (04) 12 (0C)
Set reference point value, reference point incorrect
Cause
Effect
Elimina-
tion
4 (04) 13 (0D)
Digital output not possible
Cause
Effect
Elimina-
tion
4 (04) 14 (0E)
Request application data incorrect
Cause
Effect
Elimina-
tion
4 (04) 15 (0F)
Teach In, program number incorrect
Cause
Effect
Elimina-
tion
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note: Value (xx) = Hexadecimal notation of the error number
11-24
Error message,
error analysis and elimination
Error response: "Warning" see Table 11-2
Value falls outside the range
Does not become effective
Input a correct value
Actual value falls outside the software limit switches or outside
9
the range
10
MSR
Set actual value does not become effective
Input a correct value
Value falls outside the range
Set reference point does not become effective
Input a correct value
Output not available for direct output of the user program
Output is not executed
Correct user program
Correct parameterization of the output assignment within the
MD35 to the desired assignment
Incorrect request code
Old application data are retained
Request code 0-6, 16-23 and 25 possible
The program was not parameterized or read in.
Teach In is not executed
Parameterize and read in program or correct program number
9
10
MSR
9
10
MSR
FM 354 Servo Drive Positioning Module
Message/
Display
CBS
or
DB
DB
CBS
or
DB
CBS
or
DB
DB
CBS
or
DB
DB
CBS
or
DB
DB
CBS
or
DB
DB