USER MAINTENANCE PROCEDURES

Cleaning the Corona Wire

Please clean the corona wire if vertical black lines appear on the printing image.
1. Lift up the operation panel.
2. Open the upper cover.
3. Remove the toner cassette. Place it on a
sheet of paper.
4. Gently drag the blue lever from end to
end twice. Make sure the lever is re-
turns to the original position.