Create a maintenance association:
3.
Enable the continuity check protocol and specify the continuity check hold interval:
4.
Configure the maintenance association end point (MEP)
5.
Results
Check the results of the configuration.
[edit]
user@switch2# show
protocols {
oam {
ethernet {
}
}
Verification
To confirm that the configuration is working properly, perform these tasks:
Verifying That OAM CFM Has Been Configured Properly on page 3467
Verifying That OAM CFM Has Been Configured Properly
Purpose
Verify that OAM CFM has been configured properly.
Action
Use the show oam ethernet connectivity-fault-management interfaces detail command:
user@switch1# show oam ethernet connectivity-fault-management interfaces detail
Sample Output
Interface name: ge-1/0/1.0, Interface status: Active, Link status: Up
Maintenance domain name: private, Format: string, Level: 0
Maintenance association name: private-ma, Format: string
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private]
user@switch2# set maintenance-association private-ma
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch2# set continuity-check hold-interval 1s
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain private maintenance-association private-ma]
user@switch2# set mep 100 interface ge-0/2/5 auto-discovery direction down
connectivity-fault-management {
maintenance-domain private {
level 0;
maintenance-association private-ma {
continuity-check {
interval 1s;
}
mep 100 {
interface ge-0/2/5;
auto-discovery;
direction down;
}
}
}
Chapter 131: Ethernet OAM Connectivity Fault Management