392
Chapter 12 Configuring the switch using Web-based management
Table 146 Port Management page items
Item
Link
Link Trap
Autonegotiation
Speed / Duplex
2
3
4
320985-A Rev 01
Range
(1) On
(2) Off
(1) Enabled
(2) Disabled
(1) 10Mbs / Half
(2) 10Mbs / Full
(3) 100Mbs / Half
(4) 100Mbs / Full
(5) 1000Mbs / Full
In the upper-left corner, click on the unit number of the Ethernet Switch 425
stack to manage.
The page is updated with the information for the selected switch.
In the port row of your choice, select from the lists.
Click Submit.
Description
The current link state of the corresponding port as
follows:
Up: The port is connected and operational
Down: The port is not connected or is not operational.
Choose to control whether link up/down traps are sent to
the configured trap receiver from the switch.
The default setting is On.
Choose to enable or disable the autonegotiation feature.
Choosing to enable autonegotiation sets the
corresponding port speed to match the best service
provided by the connected station, up to 100Mb/s in
full-duplex mode.
Note: Autonegotiation also enables auto sensing on 10/
100 ports.
The default setting is Enabled.
Choose the Ethernet speed you want the port to
support.
The default setting is 10 Mbs/Half when autonegotiation
is disabled and 1000 Mb/s full-duplex for gigabit ports
only.