176 Chapter 4 Getting Started with Device Manager
Table 30
Table 30 Open Device dialog box fields
Field
Device Name
Read Community
Write Community
v3 Enabled
User Name
Authentication
Protocol
Authentication
Password
Privacy Protocol
Privacy Password
2
3
4
320985-A Rev 01
describes the Open Device dialog box fields.
Description
Either an IP address or a DNS name for the device, entered by
the user.
SNMP read community string for the device. Default is
(displayed as ******). The entry is case-sensitive.
SNMP write community string for the device. Default is
private
When selected (enabled), Open Device dialog box will display
SNMPv3 options.
Indicates the name of the user.
Identifies the authentication protocol used.
Specifies the current authentication password.
Identifies the privacy protocol.
Specifies the current privacy password.
In the Device Name text box, type the DNS name or IP address of the device.
In the Read Community and Write Community text boxes, type the
appropriate community strings.
Note: To gain read/write access to a device in Device Manager, you
must enter the read/write community string for both the Read
Community and Write Community strings.
Click Open.
Device Manager automatically determines what version of software the
selected device is running and displays the appropriate Device Manager
dialog boxes.
The Device Manager window opens, showing a picture of the device
(Figure 57)
that represents the physical features of the device.
(displayed as *******).The entry is case-sensitive.
public