Nortel 325-24T Configuration Manual page 222

Ethernet switches 325 and 425
Hide thumbs Also See for 325-24T:
Table of Contents

Advertisement

222
Chapter 6 System configuration using the Console Interface
Table 49
Table 49 System Characteristics screen fields
Field
Operation Mode
Size of Stack
Base Unit
MAC Address
Reset Count
Last Reset Type
Power Status
Local GBIC Type
sysDescr
sysObjectID
sysUpTime
320985-A Rev 01
describes the System Characteristics screen fields
Description
Read-only field that indicates the operation mode of the unit, for example:
When the unit is part of a stack configuration, the (read-only) field indicates the
unit is operational in a stack, and lists the current unit number of this switch. In
this example (see
Figure 81 on page
When the unit is not part of a stack configuration (operating standalone), the
read-only field indicates the unit is operating as a switch. When in this operation
mode, the Size of Stack and Base Unit fields (see following description) do not
appear.
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the number of units configured in the stack
configuration (1 to 8 units maximum).
This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the unit number of the switch that is currently
operating as the base unit.
The MAC address of the switch or, when the switch is participating in a stack
configuration, the MAC address of the stack configuration.
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default Value
1
Range
0 to 2
A read-only field that indicates the last type of reset.
Default Value
Power Cycle
Range
Power Cycle, Software Download, Management Reset,
Management Factory Reset
A read-only field that indicates the current power source (primary, RPSU, or both).
Default Value
Primary Power
Range
Primary Power, Redundant Power, Primary and Redundant
Power
A read-only field that indicates the GBIC type that is configured in this unit. (This field
is applicable only to the Ethernet Switch 425).
A read-only field that specifies hardware and software versions.
A read-only field that provides a unique identification of the switch, which contains
the vendor's private enterprise number.
A read-only field that shows the length of time since the last reset. Note that this field
is updated when the screen is redisplayed.
221), the current unit number is Unit 2.
-1 (4,294,967,295)
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

325-24g425-24t425-48t

Table of Contents