COMMAND REFERENCE
Example:
Send
CONFigure:AC (@2)
Send
SENSe:SWEep:REALtime ON
Send
TRIGger:SOURce INTernal2
Send
TRIGger:LEVel .02
Send
TRIGger:SLOPe EITHer
Send
INITiate
Send
FETch:AC? (@2)
Read
<AC-RMS voltage>
Front panel compliance:
The TRIGger:SLOPe command is the remote equivalent of the front panel TRIG1,
TRIG2, TRIG3, and TRIG4 keys and the TRIGGER MAIN TB edge option of the
TRIGGER menu.
Configures AC-RMS CH2.
Sets real-time mode on.
Trigger source becomes
channel 2.
Trigger level becomes 20 mV.
Triggering is done at positive
(rising) and negative (falling)
trigger edges.
Initiates acquisition.
Fetches AC-RMS value.
Reads AC-RMS value.