6.5.5.1 Console Event Log

If problems occur during SRM console power-up, standard error messages indicated by
asterisks (***) may be embedded in a console event log. To display the event log, use the more
el or cat el command.
_____________________________ Note____________________________
The cat el command displays the console event log in a scrolling display. To stop
the screen display from scrolling, press Ctrl/S. To resume scrolling, press Ctrl/Q.
The more el command displays the console event log one screen at a time.
______________________________________________________________

Example 6-3 Console Event Log

>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST
STR status
CSC status
PChip0 status
PChip1 status
DIMx status
TIG Bus status
DPR status
CPU speed status = 0
CPU speed
Powerup time
CPU SROM sync
*** Error - Fan 1 failed ***
*** Error - Fan 2 failed ***
= 1
= 1
= 1
= 1
= 1
= 0
= 1
= 0
= 0
= 00-00-00 00:00:00
= 0