Syntax
buildfru ( <fru_name> <part_num> <serial_num> [<model> [<alias>]]
or
-s <fru_name> <offset> <byte> [<byte>...] )
Arguments
<fru_name>
<part_num>
<serial_num>
<model>
<alias>
<offset>
<byte>...
Options
-s
Example
P00>>>show fru | grep CPU
SMB0.CPU0
SMB0.CPU1
SMB0.CPU2
SMB0.CPU3
P00>>>
P00>>>
P00>>>buildfru smb0.cpu0 30-12345-09.b01 ni90212345 digital digital
P00>>>gct
P00>>> init
...
P00>>>show fru | grep CPU
SMB0.CPU0
SMB0.CPU1
SMB0.CPU2
SMB0.CPU3
P00>>>
6–24 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
Console name for this FRU. This name reflects the position of the FRU in
the assembly hierarchy and has the form:
<frun>[.<frun>[.<frun>[.<frun>[<frun>]]]], where "fru" is a placeholder for
the FRU type at that level and "n" is the instance of that FRU type at that
level.
The FRU's Digital 2-5-2.4 part number. This ASCII string should be 16
characters (extra characters are truncated). This field should not contain any
embedded spaces. If a space must be inserted, enclose the entire argument
string must in double quotes. This field contains the FRU revision, and in
some cases an embedded space is allowed between the part number and the
revision.
The FRU's Digital serial number. This ASCII string must be 10 characters
(extra characters are truncated). The manufacturing location and date are
extracted from this field.
The FRU's model name or number or a.k.a. name. This ASCII string may be
up to 10 characters (extra characters are truncated). This field is optional,
unless <alias> is specified.
The FRU's Compaq alias number, if one exists. This ASCII string may be
up to 16 characters (extras are truncated). This field is optional.
The beginning byte offset (hex) within this FRU's EEPROM, where the
following supplied data bytes are to be written.
The data bytes to be written (up to 16). At least one data byte must be
supplied after the offset.
Writes raw data to the EEPROM. This option is typically used to apply any
FRU specific data.
0 54-12345-01
0 54-12345-01
0 54-12345-01
0 54-12345-01
<== Need to rebuild in memory FRU tree
0 30-12345-09.B01
0 54-12345-01
0 54-12345-01
0 54-12345-01
AY80112345
AY80112345
AY80112345
AY80112345
NI90212345
DIGITAL
AY80112345
AY80112345
AY80112345
š
œ

DIGITAL

Advertisement

Table of Contents
loading

Table of Contents