Displaying The System Environment - Compaq ES40CSLP Installation, User & Service Manual

Rackmount system
Table of Contents

Advertisement

Remote System Management

4.7.3 Displaying the System Environment

Use the RMC env command to get a snapshot of the system environment, including the state of
CPUs, fans, and power supplies.
RMC>env
System Hardware Monitor
Temperature (warnings at 45.0°C, power-off at 50.0°C)
CPU0: 26.0°C
Fans RPM
Fan1: 2295
Fan4: 2235
Power Supplies(OK, FAIL, OFF, '----' means not present)
PS0 : OK
CPU0: OK
CPU CORE voltage
CPU0: +2.192V
CPU IO voltage
CPU0: +1.488V
Bulk voltage
+3.3V Bulk: +3.328V
c
CPU temperature. In this example four CPUs are present.
š
Fan RPM. All fans operate as long as the system is powered on. Fans 1 through 4 are the
system fans and Fan 5 is the PCI fan.
The normal power supply mode is either OK (system is powered on) or OFF (system is
powered off or the power supply cord is not plugged in). FAIL indicates a problem with a
supply.
œ
CPU CORE voltage and CPU I/O voltage. In a healthy system, the readings for all CPUs
should be the same.

Bulk power supply voltage.
4–10 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
CPU1: 26.0°C
Fan2: 2295
Fan5: 2500
PS1 : ----
CPU1: OK
CPU1: +2.192V
CPU1: +1.488V
+5V Bulk: +5.076V
Vterm: +1.824V
Cterm: +2.000V
CPU2: 27.0°C
CPU3: 26.0°C
Fan3: 2205
PS2 : ----
CPU2: OK
CPU3: OK
CPU2: +2.192V
CPU3: +2.192V
CPU2: +1.488V
CPU3: +1.488V
+12V Bulk: +12.096V
-12V Bulk: -12.480V
š
œ
