In the following example, the dump command dumps FE bytes from address 10.
RMC>dump
addr> 10
count> fe
0010:03 31 07 28 01 09 00 00 00 00 00 00 00 00 00 00
0020:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0030:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0040:01 80 01 01 01 01 01 01 00 00 00 00 00 00 00 00
0050:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0060:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0070:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0080:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0090:00 00 00 00 00 00 00 00 00 00 1D 00 19 18 19 00
00A0:00 00 00 00 00 00 00 00 00 00 00 FF FF FA FA 3B
00B0:00 00 00 00 00 00 00 00 00 00 BA 00 00 00 00 00
00C0:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00D0:00 00 00 00 00 00 00 00 00 00 22 00 00 00 00 00
00E0:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00F0:00 00 00 00 00 00 00 00 00 10 00 00 00 0A 03 0A
RMC>

6.7.6.2 env

The env command displays the system environmental status, including power supplies,
voltages, fans, and temperatures. If a fault has occurred, the reading blinks. The env command
is fully described in Chapter 4.

6.7.6.3 error

The error command is similar to the SRM show error command. The RMC reads information
in the shared RAM FRU EEROM locations to determine what errors have occurred. The
following example shows an error on CPU0.
RMC>error
dev>cpu0
Entry Fail Address Bank
0
RMC>
6–58 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
0be21e00
1
Source Event Type
1
00