Ricoh Z-P2 Field Service Manual page 423

Table of Contents

Advertisement

5074
[Home Key Customization] Not used
Sets applications that appear on the operation panel when the [Home] key is pressed.
5-074-002 Login Setting
5-074-050 Show Home Edit
5-074-091 Function Setting
5-074-092 Product ID
5-074-093 Application Screen ID
5083
[LED Light Switch]
Turns on or off the LED at the toner near end or waste toner near end.
5-083-001 Toner Near End
5-083-002 Waste Toner Near End
5131
[PSize/Type Select]
*CTL
[0 to 0xFF / 00000000 / 1/step]
Sets login operation mode for panel display.
*CTL
[0 to 2 / 0 / 1/step]
0: Function disable
1: SDK application
2: Legacy application (reserved)
*CTL
[0 to 2 / 0 / 1/step]
0: Function disable
1: SDK application
2: Legacy application (reserved)
*CTL
[0 to 0xFFFF FFFF/ 0 / 1/step]
Sets the application product ID.
*CTL
[0 to 255 / 0 / 1/step]
Sets the display category of the application that is
specified in the SP5075-001
Setting for future function enhancement.
*CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
*CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Engine SP Mode Tables - SP5000