5. System Maintenance Reference
1-105-233 F:M-thick:D:Press
1-105-234 Glssy:Pln1:D:Prs
1-105-235 Glssy:Pln2:D:Prs
1-105-236 Glssy:MThk:D:Prs
1-105-237 F:Thick1:D:Press
1-105-238 F:SP1:D:Press
1-105-239 F:SP2:D:Press
1106
1-106-001 F-Roller:Center
1-106-002 Fusing Roller:End
1-106-003 P-Roller:Center
1108
[Ready Temp Set]
Japan use only
1-108-007 Ready Temp Time
1109
[Fusing Nip Chck]
1-109-001
Execute
284
[FusingTemp Displ] Fusing Temperature Display (Heating or Pressure)
Displays the current temperature of the heating and pressure rollers.
The heating roller has two lamps. One heats the center of the heating roller and the
other heats both ends of the heating roller.
The pressure roller has a one lamp.
*ENG
[50 to 160 / 90 / 1 deg/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
ENG
[–20 to 250 / 0 / 1 deg/step]
ENG
[–10 to 250 / 0 / 1 deg/step]
ENG
[–10 to 250 / 0 / 1 deg/step]
*ENG
[22 to 60 / 43 / 0.1 sec/step]
ENG
[0 or 1 / 0 / 1]
Executes the nip band measurement
between fusing belt and pressure roller.
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.