Ricoh Z-P2 Field Service Manual page 428

Table of Contents

Advertisement

5. System Maintenance Reference
5-401-240 Detail Option
Enalbes or disables the log out confirmation option.
5402
[Access Control]
5-402-101 SDKJ1 Limit Setting
5-402-102 SDKJ2 Limit Setting
5-402-103 SDKJ3 Limit Setting
5-402-104 SDKJ4 Limit Setting
5-402-105 SDKJ5 Limit Setting
5-402-106 SDKJ6 Limit Setting
5-402-107 SDKJ7 Limit Setting
5-402-108 SDKJ8 Limit Setting
5-402-109 SDKJ9 Limit Setting
5-402-110 SDKJ10 Limit Setting
5-402-111 SDKJ11 Limit Setting
5-402-112 SDKJ12 Limit Setting
5-402-113 SDKJ13 Limit Setting
5-402-114 SDKJ14 Limit Setting
5-402-115 SDKJ15 Limit Setting
5-402-116 SDKJ16 Limit Setting
426
• Bit 0: Log out confirmation option
0: Enable (default), 1: Disable
Selects the automatic log out time.
• Bit 1 and 2: Automatic log out timer reduction
00: 60 seconds (default), 01: 10 seconds,
10: 20 seconds, 11: 30 seconds
*CTL
-
*CTL
[0 to 0xFF / 00000000 / 1/step]
bit0: SDKJ Authentication
*CTL
-0: Panel Type
*CTL
-1: Remote Type
*CTL
bit1: Using user code setup
-0: OFF, 1: ON
*CTL
bit2: Using key-counter setup
*CTL
-0: OFF, 1: ON
*CTL
bit3: Using external billing device setup
*CTL
-0: OFF, 1: ON
bit4: Using extended external billing device
*CTL
setup
*CTL
-0: OFF, 1: ON
bit5 to 6: Not used
*CTL
bit7: Using extended function J limit users
*CTL
-0: OFF, 1: ON
*CTL
*CTL
*CTL
*CTL

Advertisement

Table of Contents
loading