No.
Type
536
D
Drive unit fan error
The motor lock signal error is detected for 10 seconds after the motor lock signal
was first detected.
• Defective drive unit fan
• Disconnected or defective harness
• Defective BCU
1. Check or replace the harness.
2. Replace the drive unit fan.
3. Replace the BCU.
No.
Type
537
D
Fusing cooling fan error
The motor lock signal error from the fusing cooling fan is detected for 10 seconds
after turning on the fusing cooling fan.
• Disconnected harness of the fusing cooling fan
• Defective fusing cooling fan
• Defective BCU
1. Check or replace the harness of the fusing cooling fan.
2. Replace the fusing cooling fan.
3. Replace the BCU.