Ricoh Z-P2 Field Service Manual page 277

Table of Contents

Advertisement

1-104-010 Upper Limit Temp
1-104-011 Offset:Feed Start
1-104-012 Offset:FdStart:MT
1-104-013 Offst:FdS600Pl1BW
1-104-014 Offst:FdS600Pl2BW
1-104-030 FdStrt Time
1-104-031 Offst:FdStrt:1200
1-104-033 Offst:FdStrt:Glsy
Engine SP Mode Tables: SP1000
*ENG
[0 to 100 / 25 / 1 deg/step]
Specifies the additional
temperature for the upper limit of
the heating roller.
*ENG
[0 to 100 / 20 / 1 deg/step]
Specifies the subtract temperature
for the lower limit of the heating
roller.
*ENG
[0 to 100 / 10 / 1 deg/step]
Specifies the subtract temperature
of the middle thick paper for the
lower limit of the heating roller.
*ENG
[0 to 100 / 25 / 1 deg/step]
Specifies the subtract temperature
of the plain 1 paper in the 600
dpi BW printing mode for the
lower limit of the heating roller.
*ENG
[0 to 100 / 25 / 1 deg/step]
Specifies the subtract temperature
of the plain 2 paper in the 600
dpi BW printing mode for the
lower limit of the heating roller.
*ENG
[15 to 500 / 60 / 1 sec/step]
Specifies the waiting time for the
paper feeding.
*ENG
[0 to 100 / 15 / 1 deg/step]
Specifies the additional
temperature in the 1200 dpi
printing mode for the upper limit of
the heating roller.
*ENG
[0 to 100 / 15 / 1 deg/step]
Specifies the additional
temperature in the glossy printing
mode for the upper limit of the
heating roller.