6. Troubleshooting
No.
Type
231
D
-003
No.
Type
231
D
-004
No.
Type
240
C
-001
241
C
-004
-
-
568
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: M
• The PFGATE ON signal still asserts within 5 seconds after processing the
image in normal job or MUSIC (line position adjustment) for end position
[M].
• The PFGATE ON signal still asserts when the next job starts.
See SC230-001 for troubleshooting details.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: C
• The PFGATE ON signal still asserts within 5 seconds after processing the
image in normal job or MUSIC (line position adjustment) for end position
[C].
• The PFGATE ON signal still asserts when the next job starts.
See SC230-001 for troubleshooting details.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
LD error: K
LD error: Y
The bridge board detects LDB error a few times consecutively when LDB unit turns
on after LDB initialization.
• Worn-out LD
• Disconnected or broken harness of the LD
1. Replace the harness of the LD.
2. Replace the laser unit.
3. Replace the bridge board.