5. System Maintenance Reference
5-413-002 Lockout Threshold
5-413-003 Cancellation On/Off
5-413-004 Cancellation Time
5414
[Access Mitigation]
5-414-001 Mitigation On/Off
5-414-002 Mitigation Time
5415
[Password Attack]
5-415-001 Permissible Number
430
*CTL
Sets a limit on the frequency of lockouts for
account lockouts.
[1 to 10 / 5 / 1 /step]
*CTL
Determines whether the system waits the
prescribed time for input of a correct user ID
and password after an account lockout has
occurred.
[0 to 1 / 0 / 1 /step]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if
correct user ID and password are entered.
*CTL
Determines the length of time that the system
waits for correct input of the user ID and
password after a lockout has occurred. This
setting is used only if SP5413-3 is set to "1"
(on).
[1 to 9999 / 60 / 1 min. /step]
*CTL
Switches on/off masking of continuously
used IDs and passwords that are identical.
[0 to 1 / 0 /1/step]
0: Off
1: On
*CTL
Sets the length of time for excluding
continuous access for identical user IDs and
passwords.
[0 to 60 / 15 / 1 min. /step]
*CTL
Sets the number of attempts to attack the
system with random passwords to gain
illegal access to the system.
[0 to 100 / 30 / 1 attempt /step]