ABB ACSM1 Manual page 96

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

96
2.12
FBA MAIN CW (continued from previous page)
Bit
10
11
12
13
14
15
16
17
18
19
20
Parameters and firmware blocks
Name
Val.
JOGGING 2
1
Activate jogging function 2. See section
page 50.
0
Jogging function 2 disabled
REMOTE
1
Fieldbus control enabled
CMD
0
Fieldbus control disabled
RAMP OUT
1
Force Ramp Function Generator output to zero.
0
Drive ramps to a stop (current and DC voltage lim-
its in force).
0
No operation
RAMP HOLD 1
Halt ramping (Ramp Function Generator output
held).
0
No operation
RAMP IN 0
1
Force Ramp Function Generator input to zero.
0
No operation
EXT1 / EXT2 1
Switch to external control location EXT2.
0
Switch to external control location EXT1.
REQ
1
Activate start inhibit.
STARTINH
0
No start inhibit
LOCAL CTL
1
Request local control for Control Word. Used when
the drive is controlled via PC tool or panel or
through local fieldbus.
- Local fieldbus: Transfer to fieldbus local control
(control via fieldbus control word or reference).
Fieldbus steals the control.
- Panel or PC tool: Transfer to local control.
0
Request external control.
FBLOCAL
1
Request fieldbus local control.
REF
0
No fieldbus local control
ABS POSIT
1
Use absolute positioning.
0
Use relative positioning.
POS START
1
Select pulse start for positioning: Start by rising
MODE
edge of a pulse.
0
Select normal start for positioning: Start by signal
rising edge. The signal has to stay TRUE during the
positioning task.
Information
Jogging
Log.
Par.
on
OR
10.14
-
-
-
-
-
-
-
-
OR
34.01
-
-
-
-
-
-
OR
65.09,
65.17
bit 4
OR
65.24