ABB ACSM1 Manual page 135

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

13.07 AI2 MAX
Defines the maximum value for analogue input AI2. The type is selected with jumper J2 on the JCU
Control Unit.
-11...11 V / -22...22 mA
13.08 AI2 MIN
Defines the minimum value for analogue input AI2. The type is selected with jumper J2 on the JCU
Control Unit.
-11...11 V / -22...22 mA
13.09 AI2 MAX SCALE
Defines the real value that corresponds to the maximum analogue input value defined by parameter
13.07 AI2
MAX.
13.09
13.08
-32768...32768
13.10 AI2 MIN SCALE
Defines the real value that corresponds to the minimum analogue input value defined by parameter
13.08 AI2
MIN. See parameter
-32768...32768
13.11 AITUNE
Triggers the AI tuning function.
Connect the signal to the input and select the appropriate tuning function.
(0) No action
(1) AI1 min tune
(2) AI1 max tune
FW block:
AI2
(see above)
Maximum AI2 input value.
FW block:
AI2
(see above)
Minimum AI2 input value.
FW block:
AI2
(see above)
AI (scaled)
13.07
AI (mA / V)
13.10
Real value corresponding to value of parameter 13.07.
FW block:
AI2
(see above)
13.09 AI2 MAX
Real value corresponding to value of parameter 13.08.
FW block: None
AI tune is not activated.
Current analogue input AI1 signal value is set as minimum value for
AI1, parameter
automatically.
Current analogue input AI1 signal value is set as maximum value for
AI1, parameter
action
automatically.
SCALE.
13.03 AI1
MIN. The value reverts back to
13.02 AI1
MAX. The value reverts back to
Parameters and firmware blocks
135
(0) No action
(0) No

Hide quick links:

Advertisement

Table of Contents
loading