ABB ACSM1 Manual page 326

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

326
Code
Fault
(fieldbus code)
0208
A2 INIT FAULT
(0x6100)
0209
STACK ERROR
(0x6100)
0210
JMU MISSING
(0xFF61)
0301
UFF FILE READ
(0x6300)
0302
APPL DIR CREATION
(0x6100)
0303
FPGA CONFIG DIR
(0x6100)
0304
PU RATING ID
(0x5483)
0305
RATING DATABASE
(0x6100)
0306
LICENSING
(0x6100)
0307
DEFAULT FILE
(0x6100)
0308
APPL FILE PAR CONF
(0x6300)
Fault tracing
Cause
Application task creation fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
JMU Memory Unit is missing or
broken.
File read error
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Drive internal fault
Note: This fault cannot be
reset.
Corrupted application file
Note: This fault cannot be
reset.
What to do
Contact your local ABB representative.
Contact your local ABB representative.
Check that the JMU is properly installed. If the
problem persists, replace the JMU.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Reload application.
If fault is still active, contact your local ABB
representative.