Homing method 13
Homing start (par. 62.03)
Home switch (par. 62.04)
Index pulse
1
If the state of the home switch is 0: Start in the negative (left) direction by the rising edge of the
signal selected by par.
SPEEDREF1.
2
Change direction by the falling edge of the home switch signal selected by par.
SWITCH
TRIG.
3
Change to homing speed 2, par.
switch signal selected by par.
4
Stop by the next index pulse.
Homing start (par. 62.03)
Home switch (par. 62.04)
Negative limit switch (par. 62.05)
1
If the state of the home switch is 0: Start in the negative (left) direction by the rising edge of the
signal selected by par.
SPEEDREF1.
2
Change direction by the rising edge of the negative limit switch signal selected by par.
NEG LIMIT
SWITCH.
3
Change to homing speed 2, par.
switch signal selected by par.
4
Stop by the next index pulse.
Homing method 13
2
3
62.03 HOMING START
62.08 HOMING
62.04 HOME SWITCH
2
Index pulse
62.03 HOMING START
62.08 HOMING
62.04 HOME SWITCH
4
with homing speed 1, par.
SPEEDREF2, by the rising edge of the home
TRIG.
Homing method 13
1
with homing speed 1, par.
SPEEDREF2, by the rising edge of the home
TRIG.
Appendix C – Homing methods
1
62.07 HOMING
62.04 HOME
3
4
62.07 HOMING
62.05
461