ABB ACSM1 Manual page 325

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Code
Fault
(fieldbus code)
0067
FPGA ERROR1
(0x5401)
0068
FPGA ERROR2
(0x5402)
0069
ADC ERROR
(0x5403)
0073
ENC 1 PULSE
FREQUENCY
(0x738B)
0074
ENC 2 PULSE
FREQUENCY
(0x738C)
0075
MOT OVERFREQUENCY
(0x7390)
0201
T2 OVERLOAD
(0x0201)
0202
T3 OVERLOAD
(0x6100)
0203
T4 OVERLOAD
(0x6100)
0204
T5 OVERLOAD
(0x6100)
0205
A1 OVERLOAD
(0x6100)
0206
A2 OVERLOAD
(0x6100)
0207
A1 INIT FAULT
(0x6100)
Cause
Drive internal fault
Drive internal fault
Drive internal fault
Encoder 1 is receiving too high
data flow (pulse frequency).
Encoder 2 is receiving too high
data flow (pulse frequency).
Inverter output (motor)
frequency has exceeded the
frequency limit 599 Hz.
Firmware time level 2 overload
Note: This fault cannot be
reset.
Firmware time level 3 overload
Note: This fault cannot be
reset.
Firmware time level 4 overload
Note: This fault cannot be
reset.
Firmware time level 5 overload
Note: This fault cannot be
reset.
Application time level 1 fault
Note: This fault cannot be
reset.
Application time level 2 fault
Note: This fault cannot be
reset.
Application task creation fault
Note: This fault cannot be
reset.
What to do
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Check encoder settings.
Change parameters
93.03 ENC1 SP
CALCMODE
and
93.13 ENC2 SP
CALCMODE
to use only one channel pulses/
edges.
Check encoder settings.
Change parameters
93.03 ENC1 SP
CALCMODE
and
93.13 ENC2 SP
CALCMODE
to use only one channel pulses/
edges.
Reduce the motor rotation speed.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.