system env temperature threshold alert

To configure the delta value from the shutdown threshold for a high or low alert to be generated, use the
system env temperature threshold alert command in global configuration mode. To return to the
default, use the no form of this command.
Syntax Description
high
low
value
Defaults
The default value is 10 degrees Celcius. An alert is sent when the temperature is 10 degrees higher or
lower than the shutdown threshold.
Command Modes
Global configuration
Command History
Release
12.2(52)EY
Examples
This example sets 15 degrees Celcius as the high value delta from the shutdown threshold so that an alert
is sent if the temperature is 15 degrees higher than the shutdown threshold:
Switch(config)# system env temperature threshold alert high 15
Switch(config)#
Related Commands
Command
show env temperature status
OL-28238-01
system env temperature threshold alert {high | low} value
no system env temperature threshold alert {high | low}
Configures the high temperature threshold when an alert should be sent.
Configures the low temperature threshold when an alert should be sent.
Specifies the delta value in degrees Celsius from the shutdown threshold for an high or
low alert to be generated. The range is from 20 to 40 degrees Celcius.
Modification
This command was introduced.
Description
Displays the switch temperature status and thresholds.
Cisco ME 3800X and ME 3600X Switch Command Reference
system env temperature threshold alert
-73