Show Env - Cisco ME 3800X Command Reference Manual

Hide thumbs Also See for ME 3800X:
Table of Contents

Advertisement

Chapter

show env

To display alarm contact, fan, temperature, and power information for the switch, use the show env
command in user EXEC mode.
Syntax Description
alarm-contact
all
fan
power
temperature
status
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.2(52)EY
Usage Guidelines
You can use the show env temperature status command to display the switch temperature status. The
command output shows the temperature state as green or red and shows the shutdown and alert
thresholds. The output from the show env all command also includes this information.
For more information about the threshold levels, see the software configuration guide for this release.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
OL-28238-01
show env {alarm-contact | all | fan | power| temperature [status]} [ | {begin | exclude | include}
expression]
Displays alarm contact status.
Displays fan, temperature, power supply, and alarm status.
Displays the switch fan status, including the power-supply fan.
Displays the switch power-supply status.
Displays the switch temperature status as GREEN or RED.
(Optional) Shows more detailed temperature status, including the temperature
value, state (green, yellow, or red), and the yellow and red threshold values.
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
Cisco ME 3800X and ME 3600X Switch Command Reference
show env
-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me 3600x