System Env Temperature Threshold Yellow - Cisco Catalyst 3750 Command Reference Manual

Hide thumbs Also See for Catalyst 3750:
Table of Contents

Advertisement

system env temperature threshold yellow

system env temperature threshold yellow
Use the system env temperature threshold yellow global configuration command on the switch stack
or on a standalone switch to specify the difference between the yellow and red temperature thresholds
and to configure the yellow threshold. Use the no form of this command to return to the default value.
Syntax Description
value
Defaults
These are the default values:
Table 2-35 Default Values for the Temperature Thresholds
Switch
Catalyst 3750G-48TS
Catalyst 3750G-48PS
Catalyst 3750G-24TS-1U
Catalyst 3750G-24PS
1. You cannot configure the red temperature threshold.
Command Modes
Global configuration
Command History
Release
12.2(25)SE
Usage Guidelines
Though visible on all switches, this command is only valid on these switches:
You cannot configure the green and red thresholds but can configure the yellow threshold. Use the
system env temperature threshold yellow value global configuration command to specify the
difference between the yellow and red thresholds and to configure the yellow threshold. For example, if
the red threshold is 66°C and you want to configure the yellow threshold as 51°C, set the difference
between the thresholds as 15 by using the system env temperature threshold yellow 15 command.
Catalyst 3750 Switch Command Reference
2-592
system env temperature threshold yellow value
no system env temperature threshold yellow value
Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 10.
Modification
This command was introduced.
Catalyst 3750G-48TS
Catalyst 3750G-48PS
Catalyst 3750G-24TS-1U
Catalyst 3750G-24PS
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
1
Yellow
Red
10°C
66°C
10°C
68°C
10°C
65°C
10°C
61°C
78-16181-03