show logging onboard
Usage Guidelines
When OBFL is enabled, the switch records all the OBFL data in a continuous, circular file. When the
continuous file is full, the switch combines the data into a summary file, which is also known as a
historical file. The switch then continues to write new data to the continuous file.
Use the start and end keywords to display data collected only during a particular time period. When
specifying the start and end times, follow these guidelines:
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Examples
This is an example of output from the show logging onboard clilog continuous command:
Switch# show logging onboard clilog continuous
--------------------------------------------------------------------------------
CLI LOGGING CONTINUOUS INFORMATION
--------------------------------------------------------------------------------
MM/DD/YYYY HH:MM:SS COMMAND
--------------------------------------------------------------------------------
05/12/2006 15:33:17 show logging onboard temperature detail
05/12/2006 15:33:21 show logging onboard voltage detail
05/12/2006 16:14:09 show logging onboard temperature summary
...
<output truncated>
....
05/16/2006 13:07:53 no hw-module module logging onboard message level
05/16/2006 13:16:13 show logging onboard uptime continuous
05/16/2006 13:39:18 show logging onboard uptime summary
05/16/2006 13:45:57 show logging onboard clilog summary
--------------------------------------------------------------------------------
This is an example of output from the show logging onboard message command:
Switch# show logging onboard message
--------------------------------------------------------------------------------
ERROR MESSAGE SUMMARY INFORMATION
--------------------------------------------------------------------------------
Facility-Sev-Name
MM/DD/YYYY HH:MM:SS
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
Cisco ME 3800X and ME 3600X Switch Command Reference
-98
hh:mm:ss—Enter the time as a 2-digit number for a 24-hour clock. Make sure to use the colons (:).
For example, enter 13:32:45.
day—Enter the day of the month. The range is from 1 to 31.
month—Enter the month in upper-case or lower-case letters. You can enter the full name of the
month, such as January or august, or the first three letters of the month, such as jan or Aug.
year—Enter the year as a 4-digit number, such as 2008. The range is from 1993 to 2035.